Oil & Gas
Heat exchangers for oil and gas in the UAE: thermal equipment engineered for upstream, midstream and refining service, built and serviced in Abu Dhabi.
View Sector
API 661 air-cooled heat exchangers and fin fan coolers in the UAE, engineered for 50°C+ Gulf ambient conditions, where water is scarce and reliable heat rejection is critical.
Staggered rows of tubes carrying the hot process fluid, each wrapped in aluminium fins that multiply the air-side surface many times over.
For representation purposes only.
Engineered against the specific failures that cost operators downtime, contamination or wasted energy.
Coolers rated for 35°C ambient collapse in a Gulf summer — process temperatures climb and trips follow exactly when demand peaks. Ambient design margin is not optional in this region, it is the whole spec.
Vibration, fan failure and fouled fins silently erode capacity until the exchanger becomes the plant bottleneck. None of these show up on a control-room screen until duty has already been lost.
Where water is scarce or expensive, air cooling removes the cooling-tower water bill entirely — if the thermal design is honest about ambient. An optimistic design temperature undoes that saving the first hot afternoon.

Forty years of Gulf operation means our ambient design assumptions are real — your cooler performs in August, not just on the datasheet.

We reverse-engineer existing bundles and re-rate them for changed duties, reusing structures and drives.

API 661 fabrication under ASME U2 Stamp at Mussafah with Local+ contribution for your procurement scoring.
What sets air-cooled heat exchangers from Dolphin Group apart, in specific and measurable terms.
No cooling tower, no chemistry, no blowdown — one less water treatment programme to run and maintain.
API 661 design rated for 50°C+ Gulf ambient conditions, not a home-market ambient assumption.
Replacement bundles re-rated and fabricated for existing structures, so the surrounding steelwork stays untouched.
ASME U2-stamped headers with full NDT and hydrotest documentation on every unit shipped.
Fin metallurgy selected for coastal and industrial atmospheres, where standard aluminium fins corrode fast.
Design and manufacturing under one roof means no subcontracted queue or handover delay — a firm delivery date, with support in place once it's running.
Design codes, materials and testing scope confirmed for every air-cooled heat exchangers order.
Design code
API 661 · ASME U2 Section VIII Div.1
Tube materials
CS · SS · Duplex · Ti (headers to match)
Fin types
Embedded (G) · Extruded · L-foot · Knurled
Fan diameter
Up to 5.5 m, forced or induced draft
Control options
Auto-variable pitch · VFD · Louvres
Design software
HTRI ACE · PV Elite
API 661 thermal design in HTRI ACE through ASME U2 code-stamped headers, engineered for real Gulf ambient extremes rather than a home-market default.
Bundle re-rating and replacement engineered to reuse existing structure, fans and drives, so only the finned surface that has failed gets replaced.
Fin cleaning, fan and drive inspection, and bundle condition assessment that catch vibration and fouling losses before they cost duty.
Scheduled bundle and fan inspection programmes that keep cooler capacity documented across every Gulf summer, not just at commissioning.
Air-Cooled Heat Exchangers in service, sector by sector, application by application.

Heat exchangers for oil and gas in the UAE: thermal equipment engineered for upstream, midstream and refining service, built and serviced in Abu Dhabi.
View Sector
Heat exchangers for power plants in the UAE: HEI-standard condensers, coolers and heat recovery equipment for conventional and renewable generation.
View Sector
Heat exchangers for petrochemical plants in the UAE: we build exchangers and reboilers for crackers, polymer plants and aromatics complexes worldwide.
View Sector
Data center cooling systems in the UAE: high-availability cooling infrastructure for the world’s fastest-growing digital economy.
View Sector
Steel plant heat exchangers and cooling equipment: furnace cooling, quench systems and dust-laden gas coolers built for the hardest environments in industry.
View Sector
Facilities management HVAC and chiller maintenance in the UAE: building services cooling and mechanical maintenance for commercial and mixed-use developments at Gulf ambient temperatures.
View SectorWe recommend 50°C dry-bulb minimum for inland UAE sites, with performance checked at the true summer peak — not the 35–40°C defaults common in imported designs.
Yes — we measure the existing bay, re-rate thermally for current duty, and fabricate drop-in bundles that reuse your structure, fans and drives.
Forced draft is cheaper to maintain and the usual default; induced draft gives better air distribution and less recirculation for tight approach duties.
Extruded aluminium fins fully sheath the tube and resist coastal corrosion best; embedded fins suit higher temperatures inland.
Variable-pitch fans, VFDs or louvres — often combined — hold outlet temperature stable across large ambient swings.
Both: complete API 661 units with structure, fans and drives, or bundles-only for retrofit.
Low-noise fan selections routinely meet 85 dB(A) at 1 m, with lower targets achievable by fan choice and tip speed.
Send bundle dimensions or the original datasheet through our RFQ form; a site measurement visit can be arranged from Mussafah within days.
Send your duty requirements or existing datasheet, and our engineers will confirm the right configuration.
Design codes, materials and testing scope confirmed for every air-cooled heat exchangers order.
Design code
API 661 · ASME U2 Section VIII Div.1
Tube materials
CS · SS · Duplex · Ti (headers to match)
Fin types
Embedded (G) · Extruded · L-foot · Knurled
Fan diameter
Up to 5.5 m, forced or induced draft
Control options
Auto-variable pitch · VFD · Louvres
Design software
HTRI ACE · PV Elite