Data Centers heat exchange equipment by Dolphin Group
Industries We Serve

Data Centers

High-availability cooling infrastructure for the world’s fastest-growing digital economy.

Scroll Down

What This Sector
Demands

Dolphin Group is an ADNOC-approved, ICV+ certified manufacturer of ASME Section VIII Div.1 and AHRI-rated plate and air-cooled heat exchange equipment engineered for 50°C+ ambient conditions and Uptime Institute tier alignment. Operating from its Mussafah, Abu Dhabi facility for over 40 years, it delivers concurrently maintainable cooling infrastructure to data centers worldwide.

Data Centers thermal equipment engineered by Dolphin Group

Extreme ambient design

Cooling equipment must deliver full duty at peak Gulf summer conditions, not nameplate lab conditions, in ambients that regularly exceed 50°C. Equipment rated only to standard lab conditions falls short of duty exactly when the load is highest.

Concurrent maintainability

Uptime tiers demand service without shutdown — equipment must be isolable, swappable and fast to clean. A cooler that cannot be isolated for cleaning forces a choice between skipped maintenance and a tier-breaking outage.

Water efficiency (WUE)

Water-side economisation and adiabatic systems must balance PUE gains against scarce water. Chasing efficiency gains without regard to water use simply trades one operating constraint for another in a water-scarce region.

Data Centers project delivered by Dolphin Group

Proven in Data Centers

Real outcomes from real data centers projects — not catalogue claims.

Colocation facility PHE package

Free-cooling plate exchanger package delivered and commissioned to meet Tier III concurrent maintainability.

ADNOC-approved, ICV+ certified

Qualified to the procurement standards ADNOC group companies require, with in-country value that scores directly on hyperscale and colocation tenders. Dolphin Group is one of roughly 70 ICV+ certified companies in the UAE, a distinction that separates us from vendors offering price alone.

Engineered for peak Gulf ambient, not nameplate lab conditions

Equipment fabricated at Mussafah is proven to deliver full duty at the extreme summer ambients data centers actually operate in. Air-cooled units are rated for 50°C+, so they hold design duty exactly when ambient load is highest, not just at standard lab conditions.

Why Data Centers
Operators Choose Dolphin

ADNOC-approved, ICV+ certified

Qualified to the procurement standards ADNOC group companies require, with in-country value that scores directly on hyperscale and colocation tenders. Dolphin Group is one of roughly 70 ICV+ certified companies in the UAE, a distinction that separates us from vendors offering price alone.

Engineered for peak Gulf ambient, not nameplate lab conditions

Equipment fabricated at Mussafah is proven to deliver full duty at the extreme summer ambients data centers actually operate in. Air-cooled units are rated for 50°C+, so they hold design duty exactly when ambient load is highest, not just at standard lab conditions.

40+ years of concurrent-maintainability experience

Four decades of isolable, swappable equipment design inform every free-cooling package we build for uptime-tier data center service. A colocation facility free-cooling plate exchanger package was delivered and commissioned to meet Tier III concurrent maintainability, servicing without shutdown.

Frequently Asked Questions

Yes. We design and supply plate heat exchangers to ASME Section VIII Div.1 and AHRI rating basis for free-cooling and chilled water loop applications.

Yes. Air-cooled equipment is rated for 50°C+ ambients, engineered to deliver full duty at peak conditions rather than nameplate lab conditions.

Yes. A colocation facility free-cooling plate exchanger package was delivered and commissioned to meet Tier III concurrent maintainability.

Yes. Equipment is engineered to be isolable, swappable and fast to clean so maintenance can happen without interrupting uptime tiers.

Yes. Plate heat exchangers and air-cooled equipment are both supplied, matched to free-cooling, chilled water and economisation strategies.

Yes. Our maintenance and overhaul programmes keep N+1 redundant cooling infrastructure genuinely redundant, not just on paper.

Yes. Dolphin Group is ADNOC-approved and ICV+ certified — one of roughly 70 ICV+ certified companies in the UAE.

Send your datasheet, TEMA sheet or existing unit nameplate details through our RFQ form or to connect@dolphin.ae — we typically respond within two working days.

Talk to Our Data Centers Engineering Team

Tell us about your duty requirements — our engineers will help you find the right heat exchange solution and get you a quote.

Talk to an Engineer